- To avoid shunt effects, a specified distance between the spot welds must be
maintained. This depends on the plate thickness:
Fig. 4-40 SPBTC48_002 Distance between spot welds
DISTANCE BETWEEN SPOT WELDS
Plate thickness
x (mm)
0.60
10
0.70
10
0.775
13
0.875
13
0.975
19
1.10
19
1.20
22
1.40
22
1.575
25
1.80
28
2.00
32
2.20
35
2.50
38
2.80
41
3.00
43
3.175
46