Connection systems for hydraulic pipes:
Connectors approved or supplied by HMC must be used at the connection points or
splices between brake pipes.
Fig. 4-72 SPBTC48_002 Brake pipe connectors
The proper torque should be applied for each type of connector.
Fig. 4-73 SPBTC41_002 Brake pipe connectors
Laying and securing of hydraulic pipes:
When installing a hydraulic pipe, the following points should be taken into account:
- HMC recommends replacing hydraulic pipes completely, instead of making
joints between pipes. The hydraulic pipes must not be welded. If it is not possi
-
ble to use one-piece pipe, the same type of connections as are used in the
original vehicle must be used.
- The pipes must be permanently fixed to the vehicle. The fixation points should
be set strategically depending on the needs and guidelines contained in this
manual.
- The distances between attachment points must not exceed 500 mm.
- When multiple wires follow the same route, it is recommended to set them all
together with straps.
BRAKE PIPE CONNECTORS
Appearance
Diameter
Ø 3.2 mm
Thread
M10 x 1.0-6H
SIZE OF THREAD
FASTENING TORQUE
TYPE A
M10
12.7~16.7 Nm