9 SHOCK ABSORBER, SWINGARM
76
- When the pressure gauge reaches the required value, turn
control lever
Damper
C,
to Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the required value.
0 bar
- When the pressure gauge reaches the required value, acti
vate the
On/Off
switch.
Guideline
0 bar
✓ The vacuum pump is switched off.
- Slide O-ring G) to the end of the special tool by the specified
value (distance
6)
minus specified value).
Guideline
5mm
I Depth micrometer (T107S) (
�
p. 296)
- Slide the floating piston into the reservoir to the shortened
position using the special tool.
•
Info
I
The floating piston must be positioned at exactly
this point when the rod is fully extended; otherwise,
damage will occur during compression of the shock
absorber.
Remove the special tool.
Remove adapter
O
from connector
8
of the vacuum
pump.
Info
Hold the damper so that the filling port is at the high
est point.
Remove the adapter.
Mount and tighten screw
@).
Guideline
I Screw, filling port
M10x1
14 Nm (10.3 lbf ft)
411