Warning
The sensors monitored a temperature
or voltage in the warning range.
• Check that the storage system’s
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41
°
F to 104
°
F (5
°
C to 40
°
C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
40
Critical
The sensors monitored a temperature
or voltage in the failure range.
• Check that the storage system’s
fans are running.
• Check that the ambient
temperature is not too warm. The
enclosure operating range is
41
°
F to 104
°
F (5
°
C to 40
°
C).
• Check for any obstructions to the
airflow.
• If none of the above explanations
apply, replace the controller FRU
that reported the error.
When the problem is fixed, event
47 is logged.
41
Informational
A vdisk spare has been added.
43
Informational
A vdisk has been deleted.
44
Warning
The controller contains dirty cache
data for the specified volume but the
corresponding disk drives are not
online.
• Determine the reason that the
drives are not online.
• If an enclosure is down,
determine corrective action.
• If the virtual disk is no longer
needed, you can clear the orphan
data; this will result in lost data.
TABLE E-1
Event Descriptions and Recommended Actions
(Continued)
Event
Code
Event Type
Description
Recommended Action
Summary of Contents for StorageWorks 2000fc
Page 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...