160
HP StorageWorks 2000 Family Modular Smart Array reference guide • August 2008
The status is OK when there are no critical or warning conditions for the element
type. If no enclosure polling data is available, a message is displayed stating this.
For information about a critical or warning condition, view the event log; see
“Viewing the Event Log” on page 171.
Controller Versions
You can view the software, hardware, and other version information for each
controller module. During normal operation, all software versions should be the
same on both controller modules. Software versions might differ briefly while you
are updating the firmware on each controller module.
To view version information:
●
Select Monitor > Status > Advanced Settings > Controller Versions.
Version information is displayed in the following four panels.
The Storage Controller Code Versions panel shows the following information:
■
Code Version – Storage Controller software version
■
Memory Controller – Memory controller software version
■
Loader Version – Storage Controller loader software version
The Management Controller Code Versions panel shows the following information:
■
Code Version – Management Controller software version
■
Loader Version – Management Controller loader software version
The Enclosure Controller Code Versions panel shows the Expander Controller
software version.
The RAID Controller Hardware Versions panel shows the following information.
■
Hardware Version – Board version number
■
CPU Type – Type of RAID controller processor:
■
Celeron 566MHz, used in a standard controller module
■
Pentium III 700MHz, used in an enhanced FC controller module
■
CPLD Version – Version of the complex programmable logic device (CPLD)
■
Host Interface Module Model – Model number of the host interface module
within a controller module
■
Host Interface Module Version – Version of the host interface module within a
controller module
■
Cache Memory Size – Cache memory size in Mbyte
Summary of Contents for StorageWorks 2000fc
Page 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...