Chapter 7
Troubleshooting Using SMU
201
4. Note any error counts displayed for these statistics.
Field
Description
SMART Event Count
The number of SMART (Self-Monitoring Analysis and
Reporting Technology) events that the drive recorded.
These events are often used by the vendor to determine
the root cause of a drive failure. Some SMART events
may indicate imminent electromechanical failure.
I/O Timeout Count
The number of times the drive accepted an I/O request
but did not complete it in the required amount of time.
Excessive timeouts can indicate potential device failure
(media retries or soft, recoverable errors)
No Response Count
The number of times the drive failed to respond to an I/O
request. A high value can indicate that the drive is too
busy to respond to further requests.
Spin-up Retries
The number of times the drive failed to start on power-up
or on a software request. Excessive spin-up retries can
indicate that a drive is close to failing.
Media Errors
The number of times the drive had to retry an I/O
operation because the media did not successfully
record/retrieve the data correctly.
Non Media Errors
The number of soft, recoverable errors that are not
associated with drive media.
Bad Block Reassignments
The number of block reassignments that have taken place
since the drive was shipped from the vendor. A large
number of reallocations in a short period of time could
indicate a serious condition.
Bad Block List Size
The number of blocks that have been deemed defective
either from the vendor or over time due to reallocation.
Summary of Contents for StorageWorks 2000fc
Page 16: ...16 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 28: ...28 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 134: ...134 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 148: ...148 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 180: ...180 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 194: ...194 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 226: ...226 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 246: ...246 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 254: ...254 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 318: ...318 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...
Page 330: ...330 HP StorageWorks 2000 Family Modular Smart Array reference guide August 2008 ...