-91
14,05 Abort : Unexpected
contact with X axis
home sensor.
14,06 Abort : Unexpected
contact with X axis EOT
sensor.
14,07 Abort : Unexpected
contact with Y axis
home sensor.
14,08 Abort : Unexpected
contact with Y axis EOT
sensor.
1. Power cycle the machine.
2. Check for an obstruction hitting the model.
3. Check to make sure the homing sensors are
clean.
4. Using LED's check if home & limit boxes are
lit. If so, check limit switches and/or
Umbilical Cable for X sensors, Y cable for
Y sensors.
5. Manually move the XY table in X and Y
checking for smooth operation.
6. Check belt tension.
7. Replace XY table. Failed bearings in the Y
drive shaft possible root cause
14,09 Abort : Unexpected
contact with Z axis
home sensor.
14,10 Abort : Unexpected
contact with Z axis EOT
sensor.
1. Check to see if the switch is operating
correctly using the LED/test points on the
PDB.
2. Check to see if there are any obstructions
interfering with Z stage movement.
14,11 Abort : Door opened
while axis in motion
1. Check to see if door latch is activating using
LED's.
2. Check J504 pins 8 and 20 on the I/O card
for loose contacts or bent pins.
3. Look at LCD display, should show "Door
Open" when machine is idle and door is
open.
4. Using LED's check to see "Door Open"
toggles when switch is activated. If not,
check door switch and/or Mid-Unit
Harness.
5. Wiggle the door, make sure the sensor
reads the magnet with movement to the
door.
6. Check that the door magnet is present.
14,13 Abort : Under Run at
vertex buffer
14,14 Abort : Under Run not in
tool path
1. Reprocess the part and send again.
2. Reorient the STL and resend.
3. If the frequency of the error is greater than
once every three months, then replace the
SBC or hard drive.
14,15 Report: Head motor
running without XY
motion
1. Software use only.
14,16 Abort : Vertex FIFO tail is
not on a 4 byte
boundary.
1. Communication error between controller
board and the SBC - Power cycle system
2. Reseat the controller board into SBC.
3. Replace controller board and/or SBC.
14,17 Abort : User abort.
1. Build was cancelled through the keypad.
14,18 Abort : User panic stop. 1. Will not be displayed on LCD (Opening
door during build can cause this error).
Code Description
Corrective Actions
Summary of Contents for DESIGNJET 3D
Page 1: ...HP Designjet 3D HP Designjet Color 3D Service Guide ...
Page 3: ......
Page 4: ... 3 ...
Page 16: ... 12 ...
Page 40: ... 24 ...
Page 52: ... 36 ...
Page 70: ... 54 ...
Page 74: ... 58 ...
Page 90: ... 74 ...
Page 172: ... 156 ...
Page 314: ... 298 Figure 272 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 315: ... 299 Figure 273 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 349: ... 333 Figure 316 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 350: ... 334 Figure 317 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 352: ... 336 ...
Page 404: ... 388 Figure 402 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 405: ... 389 Figure 403 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 458: ... 442 ...