-342
Figure 321: Service Calibration button sequence
3. Press the
Edit Configuration
button.
4. Press the
Next...
button.
5. Press the
Next...
button.
6. Press the
XTIP
(X tip offset) button.
7. Enter the calibration value by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
8. When finished, press
Done...
9. Press the
YTIP
(Y tip offset) button.
10. Enter the calibration value by pressing the
Increment
,
Decrement
and
Next Digit
buttons.
11. When finished, press
Done...
12. Press the
Next...
button until you reach the last page.
13. Press the
Done...
button.
14. Press the
Save and reboot
button.
15. The printer will reboot and return to idle.
16. Perform automatic XY Tip Calibration, see
NOTE: The value for XTIP must be between 0.7300” and 0.8300”,
For example, the value from
is + 2, you would increment
the current value by +0.002”.
NOTE: The value for YTIP must be between -0.0500” and 0.0500”,
For example, the value from
is - 4, you would decrement
the current value by -0.004”.
Button 0
Button 1
Button 2
Button 3
Summary of Contents for DESIGNJET 3D
Page 1: ...HP Designjet 3D HP Designjet Color 3D Service Guide ...
Page 3: ......
Page 4: ... 3 ...
Page 16: ... 12 ...
Page 40: ... 24 ...
Page 52: ... 36 ...
Page 70: ... 54 ...
Page 74: ... 58 ...
Page 90: ... 74 ...
Page 172: ... 156 ...
Page 314: ... 298 Figure 272 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 315: ... 299 Figure 273 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 349: ... 333 Figure 316 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 350: ... 334 Figure 317 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 352: ... 336 ...
Page 404: ... 388 Figure 402 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 405: ... 389 Figure 403 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 458: ... 442 ...