-344
6. Once the system displays Idle, press
Maintenance>System>Test Parts
then
select
the
test_XY_cal
part.
7. When part is completed, remove from printer and let cool for five min-
utes.
8. Locate the filled circle, this indicates the front of the substrate, see
Figure 323: Locating the Filled Circle (B)
9. Using a digital caliper, measure and record the diameter of circle B
along the center line between A and C, see
Figure 324: Measuring diameter of B
10. Next measure and record the distance from the outside edges of circle A
and B, see
not
seated on the small
bump of circle A.
NOTE: Reference letters are not actually “printed” on the part. If
needed, use the Part Measurement Equations sheet to record the
values. See
Summary of Contents for DESIGNJET 3D
Page 1: ...HP Designjet 3D HP Designjet Color 3D Service Guide ...
Page 3: ......
Page 4: ... 3 ...
Page 16: ... 12 ...
Page 40: ... 24 ...
Page 52: ... 36 ...
Page 70: ... 54 ...
Page 74: ... 58 ...
Page 90: ... 74 ...
Page 172: ... 156 ...
Page 314: ... 298 Figure 272 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 315: ... 299 Figure 273 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 349: ... 333 Figure 316 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 350: ... 334 Figure 317 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 352: ... 336 ...
Page 404: ... 388 Figure 402 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 405: ... 389 Figure 403 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 458: ... 442 ...