Figure 320: Example XY Tip Calibration Part.
This example requires an adjustment of X = + 2 mils, Y = - 4 mils
Entering XY Tip Calibration values manually (Firmware version 9.1 or newer)
XY Tip is the XY distance from model tip to the support tip. To move support
roads to the right (+X), apply a positive offset. To move support roads to
the back (+Y), apply a positive offset. If the calibration model is too far off
to read, these values may be set to default as a starting point for
calibration. The default values are X: 0.780” and Y: 0.000”.
1. While the printer is at
Idle
, enter standby mode by pressing the
Standby...
button.
2. Enter the Service Calibration menu by pressing the following button
sequence on the display panel:
3,2,3,3,1
. See
NOTE: Unusual circumstances may require that the XY Tip
Calibration values be entered manually. To change these values,
see
“Entering XY Tip Calibration values manually (Firmware version
Summary of Contents for DESIGNJET 3D
Page 1: ...HP Designjet 3D HP Designjet Color 3D Service Guide ...
Page 3: ......
Page 4: ... 3 ...
Page 16: ... 12 ...
Page 40: ... 24 ...
Page 52: ... 36 ...
Page 70: ... 54 ...
Page 74: ... 58 ...
Page 90: ... 74 ...
Page 172: ... 156 ...
Page 314: ... 298 Figure 272 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 315: ... 299 Figure 273 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 349: ... 333 Figure 316 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 350: ... 334 Figure 317 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 352: ... 336 ...
Page 404: ... 388 Figure 402 HP Designjet 3D measurement points and worksheet BL FL FR BR ...
Page 405: ... 389 Figure 403 HP Designjet Color 3D measurement points and worksheet BL FL FR BR ...
Page 458: ... 442 ...