-428
Gantry
The gantry controls the adjustment for the XY gantry. These values are set in
the factory and do not need to be adjusted unless the XY gantry is adjusted
or replaced where part based calibration is required.
Temperatures
The temperature control dialog allows you to adjust the set points for the
head and chamber temperatures, for both modeling and at standby. These
are set at the factory and should only be changed if noted to be incorrect.
Temperature Limits
Temperature
Building Set Point
Standby Set Point
Head
310
◦
C
100
◦
C
Support
310
◦
C
100
◦
C
Chamber
77
◦
C
77
◦
C
Temperature
Min.
Max
Head
89.5
333
Support
89.5
333
Chamber
40
77