FUEL SYSTEM (PGM-FI)
5-33
2. O
2
Sensor Heater Resistance Inspection
Turn the ignition switch OFF.
Disconnect the O
2
sensor 4P (Black) connector
and measure the resistance at the O
2
sensor con-
nector terminals of the sensor side.
Is the resistance within 10 – 40
Ω
(20
°
C/68
°
F)?
YES
–
GO TO STEP 3.
NO
–
Faulty O
2
sensor
3. O
2
Sensor Heater Power Input Line Inspection
Turn the ignition switch ON and engine stop
switch " ".
Measure the voltage between O
2
sensor 4P
(Black) connector of the wire harness side and
ground.
Is there battery voltage?
YES
–
GO TO STEP 4.
NO
–
Open circuit in the Black/white wire
4. O
2
Sensor Heater Open Circuit Inspection
Turn the ignition switch OFF.
Disconnect the ECM 33P (Light gray) connector.
Check the continuity between the ECM 33P
(Light gray) connector and O
2
sensor 4P (Black)
connector of the wire harness side.
Is there continuity?
YES
–
GO TO STEP 5.
NO
–
Open circuit in Black/green wire
5. O
2
Sensor Heater Short Circuit Inspection 2
Connect the ECM 33P (Light gray) connector.
Check for continuity between the O
2
sensor
heater 4P (Black) connector of the wire harness
side and ground.
Is there continuity?
YES
–
Short circuit in Black/green wire
NO
–
Replace the ECM with a known good
one, and recheck; refer to Key Registra-
tion Procedures (page 21-6)
CONNECTION: White – White
4P (Black) CONNECTOR
(Sensor side/female terminals)
White
White
CONNECTION: Black/white (+) – Ground (–)
Black/white
4P (Black) CONNECTOR
(Wire side/male terminals)
CONNECTION: B2 – Black/green
TOOL:
Test probe
07ZAJ-RDJA110
33P (Light gray)
CONNECTOR (Wire
side/female terminals)
B2
TERMINAL
4P (Black)
CONNECTOR (Wire
side/male terminals)
Black/
green
CONNECTION: Black/green – Ground
Black/green
4P (Black) CONNECTOR
(Wire side/male terminals)
Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys.