Communication Timing 5-59
External device
ESC2
73H
ESC2
74H
ACK
ACK
T
T
On-line
Off-line
Off-line
IJ printer
External device
IJ printer
ESC2
75H
ACK
STX
Text
ETX
T
5.5.2-3 On-line/Off-line Transmission
T Maximum time (ms)
50
5.5.2-4 Current time output Transmission
Baud rate (bps)
T Maximum time (ms)
150 to 1200
15
2400 to 115200
5
Time T2 when there is a data matrix, QR code and GS1 DataBar setting
Barcode type
Character size
T2 Minimum time (ms)
Within 24 items
25 items or more
Data matrix
5
×
8
58
250
12
×
16, 18
×
24
85
600
QR code
QR (21
×
21)
300
600
QR (25
×
25)
400
600
QR (29
×
29)
500
700
GS1 DataBar
60
250
(N : Number of Barcode)
*7 If the communication time interval is not sufficiently secured, it may not operate normally.