Transmission Sequences 5-7
(9) Any data transmitted by communication (print contents, print specifications, print
format, and user pattern) is not stored except in the following cases.
[Conditions for storing the data]
When the ink is stopped after communication by the Shut down key or a stop signal.
At 01 minute of every hour.
(10) Transmit to the existing print item after creating a transmission objective print item.
2
1
5.3.2 Printings Transmission
5.3.2-1 Text
(1) When printings are to be changed
DLE
Item
number
Printings
(2) If deleting character string within print item
DLE
Item
number
(3) When multiple printings are to be designated
DLE
Item
number
Printings
DLE
Item
number
Printings change
Printings erasure
●
Multiple print items can be consecutively transmitted within one session.
●
Print items are to be designated by specifying the item numbers. The item numbers need not be sorted
●
Print items not transmitted are not changed.
●
When “the number of the print items” and the print items are transmitted at a item by
Number-of-the-print-items specifying transmission, the print items beyond “the number of the print
items” will be deleted.
●
Number-of-the-print-items specifying transmission shall NOT be made with the other data, such as the
print format or the print specification.
●
Both calendar characters and count characters can be transmitted.
●
If printings are transmitted for a print item for which Micro QR setup is completed, a communication
error occurs.
●
If transmission is made to the item number(s) which does NOT exist, the new item number(s) of the
message will be added, which format type is either ''Individual'' or ''Free layout''.
(4) When the print contents are changed by specifying the number of the print items
ESC2
Header 7BH
DLE
Item
number
Printings
Printings change
Number of the print
items specified