5-10
●
Transmission Sequences
5.3.3 Print Data Recall Transmission
5.3.3-1 Text
ESC2
Header 20H
Classification
31H
1000s place
100s place
10s palce
Units place
Print data message number (0001 to 2000)
5.3.3-2 Print data message number
●
An already saved print data number is to be designated as the print data message number.
●
The message number is expressed by a combination of three ASCII codes.
5.3.3-3 Example of print contents transmission
(1) Example of specifying 4-digit print data registration No.
02H
1FH
20H
31H
30H
30H
31H
32H
03H
STX
ESC2
1
0
0
1
2
ETX
[Transmission results]
Calls print data of print data message number 12.
ESC
Header 56H
100s place
10s place
Units place
Print data message number (001 to 999)
ESC
Header 26H
10s place
Units place
Print data message number (01 to 99)
[Existing machine message] Existing machine message can also be used.
Header, classification
Print data message number