![background image](http://html.mh-extra.com/html/hitachi/ux-twin-nozzle/ux-twin-nozzle_technical-manual_143810079.webp)
5-26
●
Transmission Sequences
(2) Count Conditions Transmission
ESC2
Header 2CH
Classification
Count
block No.
Setting
value
Classification
Item name
Setting value
31H
Initial value
Character code
32H
Range 1
Character code
33H
Range 2
Character code
34H
Update setting range (In progress)
000000 to 999998
35H
Update setting range (Unit)
000001 to 999999
36H
Increment setting range
01 to 99
37H
Direction
0: up, 1: down
38H
Jump from
Character code
39H
Jump to
Character code
3AH
Reset
Character code
3BH
Reset signal (option)
0:signal 1, 1:signal 2
3EH
External signal count (option)
0: Disable, 1: Enable
Character code of setting value
Mode
Alphanumeric
User pattern
1-byte mode
ASCII
ASCII
2-byte mode
ASCII
2-byte code
Calendar block No.
(1 to 8)
*) When count characters has been divided (e.g., [ CC CC ]), transmit four-digits characters.