Device Compliance Statement
Item
Description
6
Summary of functional elements for use
when constructing device specific com
-
mands, and whether compound com
-
mands or program headers can be used:
The followings can be used
•Program message
•Program message terminator
•Program message unit
•Program message unit separator
•Command message unit
•
Query message unit
•Command program header
•
Query program header
•Program data
•Character program data
•Decimal program data
•Compound commands and program headers
7
Buffer capacity limitations for block data
Block data is not used.
8
Summary of program data elements used
in expressions, and deepest nesting level
allowable in sub-expressions, including
syntax restrictions imposed by the device.
Sub-expressions are not used. Character data and decimal data
are the only program data elements used.
9
Response syntax for queries
See the bundled LCR Application Disc.
10
Transmission congestion relating to
device-to device messages which do not
conform to the general principles for basic
response messages
There are no device to device messages.
11
Response capacity for block data
Block data does not appear in responses.
12
Summary of standard commands and que
-
ries used
See the bundled LCR Application Disc.
13
Device state after a calibration query has
been completed without any problem
The "
*
CAL?
" query is not used.
14
Existence/nonexistence of "
*
DDT
" com
-
mand
The "
*
DDT
" query is not used.
15
Existence/nonexistence of macro com
-
mand
Macros are not used.
16
For queries related to identification, expla
-
nation
of the response to the "
*
IDN?
" query
See "
*
IDN?
" in the Communications Instruction Manual on the
bundled LCR Application Disc.
17
Capacity of the user data storage area
reserved for when the "
*
PUD
" command
and the "
*
PUD?
" query are being executed
The "
*
PUD
" command and the "
*
PUD?
" query are not used. Fur
-
ther, there is no user data storage area.
18
Resources when the "
*
RDT
" command
and the "
*
RDT?
" query are being used
The "
*
RDT
" command and the "
*
RDT?
" query are not used. Fur
-
ther, there is no user data storage area.
19
Conditions which are influenced when
"
*
RST
", "
*
LRN?
", "
*
RCL?
", and "
*
SAV
" are
used
"
*
LRN?
", "
*
RCL?
", and "
*
SAV
" are not used. The"
*
RST
" com
-
mand returns the instrument to its initial state.
See "
*
RST
" in the Communications Instruction Manual on the
bundled LCR Application Disc.
20
Scope of the self-testing executed as a
result of the "
*
TST?
" query
See "
*
TST?
" in the Communications Instruction Manual on the
bundled LCR Application Disc.
21
Additional organization of the status data
used in a device status report
See the Communications Instruction Manual on the bundled LCR
Application Disc
22
Whether commands are overlap or se-
quential type
All commands except
:MEASure?
,
:MEMo-
ry?
,
:CORRection:OPEN
,
:CORRection:SHORt
,
and
:CORRection:LOAD
are sequence commands.
23
Criterion relating to the functions required at
the instant that the termination message is
produced, as a response to each command
Termination occurs when the command has been parsed.
10
9
8
7
6
5
4
3
2
1
Appx.
Summary of Contents for IM3536
Page 20: ...16 Operating Precautions ...
Page 34: ...30 Screen Layout and Operation ...
Page 140: ...136 Testing the System Self diagnosis ...
Page 224: ...220 About Measurement Times and Measurement Speed ...
Page 240: ...236 Discarding the Instrument ...