Manual Operation and Setup | Calibrating 3-D touch probes
17
760
HEIDENHAIN | TNC 640 | Conversational Programming User's Manual | 10/2017
Calibrating the effective radius and compensating
center misalignment
HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.
When calibrating the ball-tip radius, the control executes an
automatic probing routine. In the first run the control finds the
midpoint of the calibration ring or stud (approximate measurement)
and positions the touch probe in the center. Then, in the actual
calibration process (fine measurement), the radius of the ball tip
is ascertained. If the touch probe allows probing from opposite
orientations, the center offset is determined during another cycle.
The property of whether or how your touch probe can be oriented
is predefined for HEIDENHAIN touch probes. Other touch probes
are configured by the machine tool builder.
After the touch probe is inserted, it normally needs to be aligned
exactly with the spindle axis. The calibration function can
determine the offset between touch probe axis and spindle axis
by probing from opposite orientations (rotation by 180°) and can
calculate and implement the necessary compensation.
The center offset can be determined only with a suitable
touch probe.
If you want to calibrate using the outside of an object,
you need to preposition the touch probe above the
center of the calibration sphere or calibration pin.
Ensure that the touch points can be approached without
collision.
The calibration routine varies depending on how your touch probe
can be oriented:
No orientation possible, or orientation in only one direction: The
control executes one approximate and one fine measurement,
and then ascertains the effective ball tip radius (column R in
tool.t).
Orientation possible in two directions (e.g. HEIDENHAIN touch
probes with cable): The control executes one approximate
and one fine measurement, rotates the touch probe by 180°,
and then executes another probing routine. The center offset
(CAL_OF in tchprobe.tp) is determined in addition to the radius
by probing from opposite orientations.
Any orientation possible (e.g. HEIDENHAIN touch probes with
infrared transmission): The control executes one approximate
and one fine measurement, rotates the touch probe by 180°,
and then executes another probing routine. The center offset
(CAL_OF in tchprobe.tp) is determined in addition to the radius
by probing from opposite orientations.
Summary of Contents for TNC 640
Page 4: ......
Page 5: ...Fundamentals ...
Page 36: ...Contents 36 HEIDENHAIN TNC 640 Conversational Programming User s Manual 10 2017 ...
Page 67: ...1 First Steps with the TNC 640 ...
Page 90: ......
Page 91: ...2 Introduction ...
Page 130: ......
Page 131: ...3 Operating the Touchscreen ...
Page 144: ......
Page 145: ...4 Fundamentals File Management ...
Page 206: ......
Page 207: ...5 Programming Aids ...
Page 236: ......
Page 237: ...6 Tools ...
Page 281: ...7 Programming Contours ...
Page 333: ...8 Data Transfer from CAD Files ...
Page 355: ...9 Subprograms and Program Section Repeats ...
Page 374: ......
Page 375: ...10 Programming Q Parameters ...
Page 478: ......
Page 479: ...11 Miscellaneous Functions ...
Page 501: ...12 Special Functions ...
Page 584: ......
Page 585: ...13 Multiple Axis Machining ...
Page 650: ......
Page 651: ...14 Pallet Management ...
Page 664: ......
Page 665: ...15 Batch Process Manager ...
Page 673: ...16 Turning ...
Page 713: ...17 Manual Operation and Setup ...
Page 797: ...18 Positioning with Manual Data Input ...
Page 803: ...19 Test Run and Program Run ...
Page 843: ...20 MOD Functions ...
Page 881: ...21 Tables and Overviews ...