Configuration
81
•
•
•
•
•
•
On the Web Page:
From the Setup Menu, arrow down to select A/D rate. Toggle between
110 or 250 to make your selection and hit Arrow down to Enter to select the desired rate.
NumAverages Parameter
The value you enter for Number of Averages (NumAverages) sets the number of weight
readings used to compute a sliding average of displayed weight. This setting is to aid in
ignoring the effects of material impact and/or vibration.
Applications requiring very quick weight readings should reduce this setting to its
minimum. If the weight is unstable, increase the averages.