Instrument Configuration
81
•
•
•
•
•
•
On the
Web page
, select the communication menu and the Ethernet TCP/IP submenu and
left click inside the Fixed IP text field and enter the IP address.
On the
HI 6500 series instrument
display, select the communication menu and use the
UP or DOWN button to select the Ethernet TCP/IP submenu, then select the Fixed IP menu
item. The current IP address for the Fixed IP value will be displayed, press the ENTER or
the RIGHT button if this value needs to be modified.
Mask Address Parameter
The Mask Address parameter, or subnet address, is used by the TCP/IP network to
determine if the host is on a local subnet or on a remote network.
On the
Web page
, select the communication menu and the Ethernet TCP/IP submenu, and
left click inside the Mask Address text field and enter the mask address.
On the
HI 6500 series instrument display
, select the communication menu and use the UP
or DOWN button to select the Ethernet TCP/IP submenu, then select the Mask Address
menu item. The current Mask Address value will be displayed, press the ENTER or the
RIGHT button if the Mask Address needs to be modified.
Gateway Address Parameter
The Gateway Address parameter, is required when the HI 6500 series instrument needs to
communicate to a remote host.
On the
Web page
, select the communication menu and the Ethernet TCP/IP submenu, and
left click inside the Gateway Address text field and enter the Gateway address.
On the
HI 6500 series instrument display
, select the communication menu and use the UP
or DOWN button to select the Ethernet TCP/IP submenu, then select the Gateway Address
menu item. The current Gateway Address value will be displayed, press the ENTER or the
RIGHT button if the Gateway Address needs to be modified.
Summary of Contents for HI 6500 Series
Page 10: ...viii Contents ...
Page 20: ...10 Chapter 2 ...
Page 72: ...62 Chapter 4 ...
Page 96: ...86 Chapter 5 Profibus DP Commands and Parameters ...
Page 97: ...Instrument Configuration 87 Serial Option Termination ...
Page 126: ...116 Chapter 5 ...
Page 156: ...146 Chapter 8 ...
Page 163: ...Troubleshooting 153 General Troubleshooting Flow Chart Index ...
Page 164: ...154 Chapter 9 A Guideline Instability Electrical and Mechanical review ...
Page 165: ...Troubleshooting 155 A1 Checking for Unstable Components in a Weighing System ...
Page 166: ...156 Chapter 9 B Guidelines for Electrical Mechanical or Configuration Issues ...
Page 167: ...Troubleshooting 157 B1 Guidelines to Verify Electrical Installation ...
Page 168: ...158 Chapter 9 B2 Guidelines to Verify Mechanical Installation ...
Page 170: ...160 Chapter 9 C Integrated Technician and Stability Test Overview ...
Page 171: ...Troubleshooting 161 E Testing for Non Return to Zero System with IT Summing Card ...
Page 173: ...Troubleshooting 163 G Calibration Errors When Performing the Calibration ...
Page 174: ...164 Chapter 9 H Mechanical Installation ...
Page 175: ...Troubleshooting 165 J Electrical Inspection ...
Page 176: ...166 Chapter 9 K Installation Check Points ...
Page 177: ...Troubleshooting 167 M Weight Processor s Front Display is Blank or Locked ...
Page 178: ...168 Chapter 9 N Analog Out HI 6510 Only ...
Page 194: ...184 Appendix A Figure D1 Assembling the Swivel Mount Enclosure on the instrument pedestal ...
Page 196: ...186 Appendix A Dimensions ...
Page 200: ...4 HI 6500 Series USER GUIDE Index ...
Page 201: ......