JUPITER CM-4400 Control Module Installation and Operating Manual
57
Jupiter Control of Encore
Figure 20. Customer-Supplied Cable for Connecting CM-4400 to New-style Encore SCB
Software Configuration
The CM-4400 connected to the Encore must be configured using the
Network Description table (
page 149
) and Serial Protocol table (
page 152
).
The Serial protocol default setting is: GNP (Grass Valley Native Protocol),
9600 baud when Jupiter is controlling Encore (
Figure 21
). The Baud rate can
be changed as long as both the Encore and CM-4400 configurations match.
Figure 21. Jupiter Controlling Encore - Serial Protocol Table
A router must be defined using the Switcher Description table (
page 156
).
Including, switcher inputs, outputs, a CP Level Set, and CP Input/Output
Sets must be defined.
Note
If Encore is controlling Jupiter, different software settings are required, see
Encore Control of Jupiter
on page 63
.
1
6
Rx−
2
7
3
Tx−
8
4
9
5
to CM-4400
Serial port
DB9P
(male)
RJ45P
(male)
Rx+ Receive plus
Rx− Receive minus
Tx+
Transmit plus
Tx−
Transmit minus
G
Ground
Belden 8723 or equivalent
= Shielded, twisted pair
Rx+
Tx+
G
to Encore SCB
RS−422 port
1
2
3
4
5
6
7
8
Tx−
Rx−
Rx+
Tx+
G
G
G
G
071826105_Customer−Supplied Cable for Connecting CM-4400 to New−style Encore SCB
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Page 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...