JUPITER CM-4400 Control Module Installation and Operating Manual
71
Connecting to Multiple Crosspoint Bus Distribution Switchers
Data Router Constraints
There are several required constraints when dealing with data routers and
path finding:
•
The software on AccuSwitch will only support the Venus DM-400B and
the Concerto Data Routers.
•
Data routers that are part of a path must be connected to the CM-4000/
44000 controllers defined as “AS” (AccuSwitch) in the Type column of
the Network Description table.
•
The physical I/O numbers must be defined in both the input and
output tables because the data routers require a switch to be made in
both directions (for the forward and return data).
•
A “SAFE” input for the data router level must be defined. This input is
used with the “Enforce” or “Advise” features.
•
The maximum number of “hops” in a data router path finding path is
2. For example, one Venus could be connected to a Concerto, which in
turn could be connected to a second Concerto.
AccuSwitch also has the ability to lock or protect a data router output. This
feature will also lock the reverse output which protects or locks the data
path in both directions.