192
JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
Board column
: The name of CM-4400 connected to the control Panel. The
source of this name is the Jupiter Network Description table.
Port column
: The port number that is configured for ESCP to which the
panel is connected. ESCP is defined in the Serial Protocol Table.
Address column
: The panel address from 1 to 16 for ESCP (serial panels)
and 1 to 64 for LAN panels. This address must be unique for panels sharing
the same CM-4400 serial port. Panels are normally shipped with a panel
address of “01.” This number is referred to as the “Device Number” on the
IP configuration page and “ID” within the L-S or LCD Panels MENU
system.
Input Sets column
: Input and output set types should be CPESXTND for
Device type CPES-SER.
In Panel columns
: This column is used only for configuring an expansion
panel. This column is not used for L-S or LCD panels.
Out Set column
: Input and output set types should be CPESXTND for
Device type CPES-SER. If the entry is an actual CP Output Set, then the
control panel will be able to control all the outputs listed in that Set.
Depending on the con tents of the set, this would allow for full-matrix or
multi-bus control.
Out Panels column
: This column is used only for configuring an expansion
panel. This column is not used for L-S or LCD panels.
Level Set column
: Select the CP Level Set name.
Override Set column
: Select the CP Override set name.
Sequence set column
: Select the CP Sequence set name.
Configuring a Control Panel for Full-matrix, Multi-bus, Or Single-bus
Control
The CP Output Set entry on the MPK Devices table determines which
outputs can be controlled by a control panel. These steps assume that the
MPK Devices table is already open.
Follow these steps to configure a Control Panel for Full-matrix, Multi-bus,
Or Single-bus Control:
1.
Click in the Output Set field that you want to change.
2.
Enter the name of the preferred CP Output Set (for full/multi−bus
operation), or select the name of a single switcher output (for single bus
operation). For more information about creating an Output Set, see
The
Control Panel Output Set
on page 179
. The source of the output names is
the Switcher Output table.
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...