JUPITER CM-4400 Control Module Installation and Operating Manual
33
Figure 3. Example Jupiter System
CM-4400
System
Controller
CC 2010 Matrix (Crosspoint bus)
cables.
Apex, Concerto,
GS 400, Trinix, or
Venus router
House SMPTE
time code required
for deterministic
switching
Binary protocol
Crosspoint (XPT) bus port
For jumper and switch
setting information, re-
fer to the installation
manual supplied with
the router.
Serial Ports
House sync
required for
vertical inter-
val switching.
Jupiter file
server
10/100baseT
LAN
CB 3000 Control Buffer
May be required when more than 50 matrix
boards are installed in switcher.
Automation
computer
VTR
ASCII protocol
RS−422/232
converter
1
master control unit
Video Processing Unit
Audio Processing Unit
Audio Processing Unit
Media con-
verter or Hub
10base2
LAN
L-S-LCD panels
Triton router
LAN 1
port
071
8
2
6
105_2
8
Apr09