46
JUPITER CM-4400 Control Module Installation and Operating Manual
Section 2 — Hardware Installation
Alarms in a Single CM-4400 Installation
If the master alarm is asserted by the main CPU watchdog timer (and
assuming that the power supply is operating properly), the CM-4400 will
be rebooted automatically.
Alarms in a Redundant CM-4400 Installation
For additional protection, a redundant CM-4400 can be installed. The
redundant CM-4400 will monitor the master CM-4400.
If a master alarm condition is detected in the master unit, control will be
switched to the redundant CM-4400 automatically. The switch over to the
redundant unit will occur almost immediately after the alarm, thus pro-
viding minimal disruption to the control system. The controlling CM-4400
is indicated by a green light on the CM’s
Activate
button (see
Figure 2 on
page 32
).
If the redundant CM-4400 is controlling the system and enters an alarm
condition and then reboots:
•
The redundant CM-4400 will retain control if the master has not recov-
ered.
•
The master CM-4400 will assume control if the master has recovered
from an earlier automatic reboot.
Manually Switching A CM-4400
To manually change the operation from the master CM-4400 to the redun-
dant CM, press the
Activate
button on the front panel of the redundant CM.
To return operation to the master CM, press the
Activate
button on the
master CM.
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Page 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...