JUPITER CM-4400 Control Module Installation and Operating Manual
297
Pro-Bel SW-P-08 Protocol
Follow these steps to enter or modify the Serial Protocol table:
1.
Select the Serial Protocol option from the Jupiter menu (Jupiter > Serial
Protocol). The Serial Protocol table will then open (
Figure 234
).
Figure 234. Example of the Serial Protocol Table
2.
Double-click the protocol box that is associated with the Serial port. A
drop-down list will show the possible protocol types.
3.
Select the P08 (SWP-08 Control Panel) protocol.
4.
Click anywhere else in the table to close the entry. The default Baud
rates will be selected automatically; however, the Baud rate may be
changed by clicking the drop down menu (
Figure 235
).
Figure 235. The P08(SW-P-08 Control Panel) Protocol on The Serial Protocol Table
5.
Click the
Apply
button and then save your changes.
Note
The serial line parameters are:
•
38400 Baud
•
8 data bits
•
No parity
•
1 stop bit
•
The baud rate is adjustable
Entering MPK information
You will need to make entries in the MPK Devices table for the port to asso-
ciate the Input, Output and Level sets. The Device Type is Serial with a
Serial Input and an Output set. The level type is cp3000.
Protocol
Baud Rate
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Page 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...