JUPITER CM-4400 Control Module Installation and Operating Manual
179
The Control Panel Output Set
The Control Panel Output Set
The Control Panel (CP) Output sets are assigned to the specific control
panels, which are defined on
The MPK Devices Table
on page 191
.
Do NOT give an Output Set the same name as an output. Using an exten-
sion such as “OUT” is recommended to help avoid potential conflicts.
Since each control panel can be assigned a different CP Output Set, these
sets are usually used to control access to outputs on a panel-by-panel basis:
•
You may want a control panel in the master control room to have access
to all possible outputs. This panel might be assigned to Output Set
“MC-OUT,” which includes a category/number entry for all destina-
tions.
•
You may want a control panel in a particular department to have access
to only a selected number of outputs. This panel would be assigned to
an Output Set (such as “NEWS-OUT”) which has only those outputs
listed.
Note
If you want the panel to be restricted to a single output, you could instead use
the technique already described, whereby the name of the output, rather than
the name of an Output Set, is entered on the MPK Devices table.
Creating a CP Output Set
For steps activating the Control Panel Set dialog, see
Creating a CP Set
on
page 171
.
Figure 127. The Control Panel Sets Dialog - Output Set
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Page 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...