208
JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
Point-to-Point Switching
Point-to-point switching insures that a source can be switched to only one
destination at a time.
Jupiter AccuSwitch supports the following router options support point-
to-point switching:
•
Advise
•
Enforce
A safe input must be configured for point-to-point switching to occur.
The SAFE input
A SAFE input must be defined before a destination can be cleared. This
input is defined by entering the word “safe” in all caps and adding two (2)
spaces at the end of the word, in the Switcher Input table (
Figure 153
). For
example:
"
SAFE
"
Figure 153. “SAFE “ in the Switcher Input Table
Point-to-Point Switching
Point-to-point switching insures that a source can be switched to only one
destination at a time (
Figure 154
).
Figure 154. Point-to-Point Switching Example
1
Name
RIGHT
VIDEO
2
TONE
3
TC
4
VT01
LEFT
TC
001
000P
001
000P
001
000P
001
Switcher Input − MAINROUT
064
I
000
I
000
I
Logical Input
SAFE
0
Editor
VCR 1
VCR 2
Data
Controller level