JUPITER CM-4400 Control Module Installation and Operating Manual
Section 5 — The Configurator Application
Remote System Routing
WAN operation of multiple Jupiter systems or Remote System routing has
been supported since the 7.4.1 release of Jupiter. Remote System routing
allows multiple Jupiter networks, with multiple routers, to be controlled
bi−directionally. See
Figure 155
below.
Figure 155. Remote System Routing Example
Notice that each AccuSwitch Controller will have only one IP address. A
CM-4000 in system1 will have only one name. A CM-4000 in system 1 could
have a different name when it is identified in system 2.
004053011C21 − 192.168.253.10 − Device 65
CM−4000 running
AccuSwitch application
“SYS2”
CM−4000 running JupiterXPress
application
(or VM−3000 running JupiterPlus)
“CM1”
MPK Bus
Jupiter system
(LAN) No. 1
(e.g.
192.168.253.x)
Matrix router
“SYS1”
Matrix router
“SYS2”
Jupiter system
(LAN) No. 2
(e.g.
192.168.254.x)
IP switch
IP switch
Jupiter File
Server
IP router
Jupiter File
Server
MPK control panel “CP1”
CM−4000 running
AccuSwitch application
“SYS1”
004053011C22 − 192.168.254.10 − Device 66
004053011C23
Contol panel (or PC) running ES−LAN
(JEP−100 shown)
System 1
or SYS1
System 2
or SYS2
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Page 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...