JUPITER CM-4400 Control Module Installation and Operating Manual
69
Connecting to Multiple Crosspoint Bus Distribution Switchers
Figure 31. Example of Non-Sequential Path Finding Connections
Path Finding with Data Routers
CM-4000 controllers running the AccuSwitch application will support two
data router models:
•
Venus data routers with DM-400B Data Matrix boards, and
•
Concerto data routers.
In addition, AccuSwitch will now support path finding (tie line operation)
between any combination of Venus DM-400B and Concerto data routers,
up to a maximum of three routers.
For example,
Figure 32 on page 70
shows a single CM-4000/AccuSwitch
controlling a Venus and Concerto connected with five tie lines. All cables
are 1−1 (pin−to−pin) including the tie line cables.
20
26 27
83
84
88
87
45 46
61
62
Crosspoint Bus
distribution switcher
“A”
Crosspoint Bus
distribution switcher
“B”
13
14
15
44
82
CC 2010 Matrix
cable. 50 ft.
(15.2 m) max.
CC 2010 Matrix cable.
50 ft. (15.2 m) max.
Hub
10/100baseT
Jupiter LAN
CM 4400 System Controller
Crosspoint Bus port
CM 4400 System Controller
Crosspoint Bus port