JUPITER CM-4400 Control Module Installation and Operating Manual
45
CM-4400 Control System’s Protection Features
CM-4400 Control System’s Protection Features
The CM-4400 has many features that are for your protection. These features
include:
•
Alarms
•
Single CM-4400
•
Redundant CM-4400
•
Redundant Units
Alarm Modes
The CM-4400’s alarm system will start in the following conditions:
•
The main CPU (or a main CPU task) is not operating properly.
•
The power supply is not operating properly.
•
The unit is in the process of rebooting.
The master alarm condition is indicated by either a “00,” “01,” or “FF” on
the front panel’s LED display, and at the rear panel’s Alarm BNC connector
(
Figure 3 on page 33
). For more information alarm conditions, see
Error
Codes
on page 260
.
The Control Module Alarm Circuit
Electrically, the Alarm BNC operates according to the SMPTE standard
269M-1999. When an alarm is asserted, the circuit associated with the
Alarm connector will present low impedance to an external current source
circuit provided by the customer.
Figure 9
shows the CM-4400 alarm circuit
(left) and an example of a customer-supplied indicator circuit (right).
Figure 9. CM-4400 Alarm Circuit
EXTERNAL CIRCUIT
(EXAMPLE)
NOT TO EXCEED
24 VDC @ 20 mA
REAR−PANEL BNC
8
6
05_r1
CM alarm circuit
Summary of Contents for JUPITER -
Page 10: ...10 JUPITER CM 4400 Control Module Installation and Operating Manual Preface ...
Page 30: ...30 JUPITER CM 4400 Control Module Installation and Operating Manual ESD Protection ...
Page 248: ...248 JUPITER CM 4400 Control Module Installation and Operating Manual Section 9 Force Unlock ...
Page 310: ...4 JUPITER CM 4400 Control Module Installation and Operating Manual Index ...