GE Multilin
M60 Motor Protection System
B-33
APPENDIX B
B.4 MEMORY MAPPING
B
4E24
Raw Field Data Brick Rx Power
0 to 0.1
dBm
0.1
F002
0
4E25
Raw Field Data Brick Diagnostics (2 items)
0 to 65535
---
1
F500
0
4E27
Raw Field Data Local Transceiver Temperature
0 to 1
degree
1
F002
0
4E28
Raw Field Data Local Transceiver Voltage
0 to 0.01
V
0.01
F001
0
4E29
Raw Field Data Local Transceiver Current
0 to 1
mA
1
F001
0
4E2A
Raw Field Data Local Tx Power
0 to 0.1
dBm
0.1
F002
0
4E2B
Raw Field Data Local Rx Power
0 to 0.1
dBm
0.1
F002
0
4E2C
Repeated for module number 2
4E58
Repeated for module number 3
4E84
Repeated for module number 4
4E80
Repeated for module number 5
4EDC
Repeated for module number 6
4F08
Repeated for module number 7
4F34
Repeated for module number 8
Flexlogic (Read/Write Setting)
5000
FlexLogic Entry (512 items)
0 to 4294967295
---
1
F300
2097152
RTD Inputs (Read/Write Setting) (48 Modules)
5400
RTD Input 1 Function
0 to 1
---
1
F102
0 (Disabled)
5401
RTD Input 1 ID
---
---
---
F205
“RTD Ip 1“
5407
RTD Input 1 Type
0 to 3
---
1
F174
0 (100 ohm
Platinum)
5408
RTD Input 1 Application
0 to 5
---
1
F550
0 (None)
5409
RTD Input 1 Alarm Temperature
1 to 249
°C
1
F001
130
540A
RTD Input 1 Alarm Pickup Delay
0 to 600
s
0.01
F001
0
540B
RTD Input 1 Trip Temperature
1 to 249
°C
1
F001
130
540C
RTD Input 1 Trip Pickup Delay
0 to 600
s
0.01
F001
0
540D
RTD Input 1 Trip Reset Delay
0 to 600
s
0.01
F001
0
540E
RTD Input 1 Trip Voting
0 to 48
---
1
F551
0
540F
RTD Input 1 Open
0 to 2
---
1
F552
0 (None)
5410
RTD Input 1 Block
0 to 4294967295
---
1
F300
0
5412
RTD Input 1 Target
0 to 2
---
1
F109
0 (Self-reset)
5413
RTD Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
5414
...Repeated for RTD Input 2
5428
...Repeated for RTD Input 3
543C
...Repeated for RTD Input 4
5450
...Repeated for RTD Input 5
5464
...Repeated for RTD Input 6
5478
...Repeated for RTD Input 7
548C
...Repeated for RTD Input 8
54A0
...Repeated for RTD Input 9
54B4
...Repeated for RTD Input 10
54C8
...Repeated for RTD Input 11
54DC
...Repeated for RTD Input 12
54F0
...Repeated for RTD Input 13
5404
...Repeated for RTD Input 14
5518
...Repeated for RTD Input 15
552C
...Repeated for RTD Input 16
5540
...Repeated for RTD Input 17
5554
...Repeated for RTD Input 18
5568
...Repeated for RTD Input 19
557C
...Repeated for RTD Input 20
5590
...Repeated for RTD Input 21
55A4
...Repeated for RTD Input 22
55B8
...Repeated for RTD Input 23
Table B–9: MODBUS MEMORY MAP (Sheet 26 of 66)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for M60 UR Series
Page 10: ...x M60 Motor Protection System GE Multilin TABLE OF CONTENTS ...
Page 128: ...4 30 M60 Motor Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 410: ...5 282 M60 Motor Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 440: ...6 30 M60 Motor Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 452: ...7 12 M60 Motor Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 462: ...9 8 M60 Motor Protection System GE Multilin 9 2 BATTERIES 9 MAINTENANCE 9 ...
Page 474: ...A 12 M60 Motor Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 584: ...B 110 M60 Motor Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 614: ...C 30 M60 Motor Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 630: ...E 10 M60 Motor Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 642: ...F 12 M60 Motor Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 644: ...G 2 M60 Motor Protection System GE Multilin G 1 RADIUS SERVER CONFIGURATION APPENDIX G G ...
Page 652: ...H 8 M60 Motor Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 662: ...x M60 Motor Protection System GE Multilin INDEX ...