![GE M60 UR Series Instruction Manual Download Page 40](http://html.mh-extra.com/html/ge/m60-ur-series/m60-ur-series_instruction-manual_130365040.webp)
2-10
M60 Motor Protection System
GE Multilin
2.2 ORDER CODES
2 PRODUCT DESCRIPTION
2
The order codes for the reduced size vertical mount units are shown below.
Table 2–5: M60 ORDER CODES (REDUCED SIZE VERTICAL UNITS)
M60
-
*
**
- *
*
* - F
**
- H
**
- M
**
-
P/R
**
Reduced Size Vertical Mount (see note regarding P/R slot below)
BASE UNIT
M60
|
|
|
|
|
|
|
|
|
Base Unit
CPU
T
|
|
|
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U
|
|
|
|
|
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-T (SFP with RJ45)
V
|
|
|
|
|
|
|
|
RS485 and Three 10/100Base-T (SFP with RJ45)
SOFTWARE
00
|
|
|
|
|
|
|
No Software Options
01
|
|
|
|
|
|
|
Ethernet Global Data (EGD)
03
|
|
|
|
|
|
|
IEC 61850
04
|
|
|
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850
28
|
|
|
|
|
|
|
Broken rotor bar detection
29
|
|
|
|
|
|
|
Broken rotor bar detection and Ethernet Global Data (EGD)
30
|
|
|
|
|
|
|
Broken rotor bar detection and IEC 61850
31
|
|
|
|
|
|
|
Broken rotor bar detection, Ethernet Global Data (EGD), and IEC 61850
A0
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
A3
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
AS
|
|
|
|
|
|
|
CyberSentry Lvl 1
AT
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
AU
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
AV
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
B0
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Broken rotor bar detection
B1
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Broken rotor bar detection and Ethernet Global Data (EGD)
B3
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Broken rotor bar detection and IEC 61850
B4
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Broken rotor bar detection and IEC 61850 and Ethernet Global Data (EGD)
BS
|
|
|
|
|
|
|
IEEE 1588
BT
|
|
|
|
|
|
|
IEEE 1588 and Ethernet Global Data (EGD)
BU
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
BV
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850 and Ethernet Global Data (EGD)
C0
|
|
|
|
|
|
|
Parallel Redundancy Protocol (PRP)
C1
|
|
|
|
|
|
|
PRP and Ethernet Global Data (EGD)
C3
|
|
|
|
|
|
|
PRP and IEC 61850
C4
|
|
|
|
|
|
|
PRP, Ethernet Global Data (EGD), and IEC 61850
CS
|
|
|
|
|
|
|
PRP and Rotor broken bar
CT
|
|
|
|
|
|
|
PRP, Rotor broken bar, and Ethernet Global Data (EGD)
CU
|
|
|
|
|
|
|
PRP, Rotor broken bar, and IEC 61850
CV
|
|
|
|
|
|
|
PRP, Rotor broken bar, Ethernet Global Data (EGD), and IEC 61850
D0
|
|
|
|
|
|
|
IEEE 1588 and Broken rotor bar detection
D1
|
|
|
|
|
|
|
IEEE 1588 and Broken rotor bar detection and Ethernet Global Data (EGD)
D3
|
|
|
|
|
|
|
IEEE 1588 and Broken rotor bar detection and IEC 61850
D4
|
|
|
|
|
|
|
IEEE 1588 and Broken rotor bar detection and IEC 61850 and Ethernet Global Data (EGD)
DS
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1
DT
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and Ethernet Global Data (EGD)
DU
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850
DV
|
|
|
|
|
|
|
IEEE 1588 and CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
E0
|
|
|
|
|
|
|
IEEE 1588 and PRP
E1
|
|
|
|
|
|
|
IEEE 1588, PRP, and Ethernet Global Data (EGD)
E3
|
|
|
|
|
|
|
IEEE 1588, PRP, and IEC 61850
E4
|
|
|
|
|
|
|
IEEE 1588, PRP, Ethernet Global Data (EGD), and IEC 61850
ES
|
|
|
|
|
|
|
IEEE 1588, PRP, and Rotor broken bar
ET
|
|
|
|
|
|
|
IEEE 1588, PRP, Rotor broken bar, and Ethernet Global Data (EGD)
EU
|
|
|
|
|
|
|
IEEE 1588, PRP, Rotor broken bar, and IEC 61850
EV
|
|
|
|
|
|
|
IEEE 1588, PRP, Rotor broken bar, Ethernet Global Data (EGD), and IEC 61850
F0
|
|
|
|
|
|
|
PRP and CyberSentry Lvl 1
F1
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and Ethernet Global Data (EGD)
F3
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and IEC 61850
F4
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Ethernet Global Date (EGD), and IEC 61850
FS
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, and Rotor broken bar
FT
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Rotor broken bar, and Ethernet Global Data (EGD)
FU
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Rotor broken bar, and IEC 61850
FV
|
|
|
|
|
|
|
PRP, CyberSentry Lvl 1, Rotor broken bar, Ethernet Global Data (EGD), and IEC 61850
G0
|
|
|
|
|
|
|
IEEE 1588, PRP, and CyberSentry Lvl 1
G1
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data (EGD)
G3
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
G4
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Ethernet Global Data (EGD), and IEC 61850
GS
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, and Rotor broken bar
GT
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Rotor broken bar, and Ethernet Global Data (EGD)
GU
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Rotor broken bar, and IEC 61850
GV
|
|
|
|
|
|
|
IEEE 1588, PRP, CyberSentry Lvl 1, Rotor broken bar, Ethernet Global Data (EGD), and IEC 61850
J0
|
|
|
|
|
|
|
IEC 60870-5-103
J1
|
|
|
|
|
|
|
IEC 60870-5-103 + EGD
J3
|
|
|
|
|
|
|
IEC 60870-5-103 + IEC 61850
J4
|
|
|
|
|
|
|
IEC 60870-5-103 + EGD + IEC 61850
JS
|
|
|
|
|
|
|
IEC 60870-5-103 + Rotor broken bar
JT
|
|
|
|
|
|
|
IEC 60870-5-103 + Rotor broken bar + EGD
JU
|
|
|
|
|
|
|
IEC 60870-5-103 + Rotor broken bar + IEC 61850
JV
|
|
|
|
|
|
|
IEC 60870-5-103 + Rotor broken bar + EGD + IEC 61850
K0
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103
K1
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + EGD
K3
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + IEC 61850
K4
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + EGD + IEC 61850
KS
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + Rotor broken bar
KT
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + Rotor broken bar + EGD
KU
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + Rotor broken bar + IEC 61850
KV
|
|
|
|
|
|
|
IEEE 1588 + PRP + IEC 60870-5-103 + Rotor broken bar + EGD + IEC 61850
L0
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1
L1
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + EGD
L3
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + IEC 61850
L4
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + EGD + IEC 61850
LS
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + Rotor broken bar
LT
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + Rotor broken bar + EGD
LU
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + Rotor broken bar + IEC 61850
LV
|
|
|
|
|
|
|
IEC 60870-5-103 + IEEE 1588 + PRP + CyberSentry Lvl 1 + Rotor broken bar + EGD + IEC 61850
MOUNT/COATING
V
|
|
|
|
|
|
Vertical (3/4 rack)
B
|
|
|
|
|
|
Vertical (3/4 rack) with harsh environmental coating
FACEPLATE/ DISPLAY
F
|
|
|
|
|
English display
D
|
|
|
|
|
French display
R
|
|
|
|
|
Russian display
A
|
|
|
|
|
Chinese display
K
|
|
|
|
|
Enhanced front panel with English display
M
|
|
|
|
|
Enhanced front panel with French display
Q
|
|
|
|
|
Enhanced front panel with Russian display
U
|
|
|
|
|
Enhanced front panel with Chinese display
L
|
|
|
|
|
Enhanced front panel with English display and user-programmable pushbuttons
N
|
|
|
|
|
Enhanced front panel with French display and user-programmable pushbuttons
T
|
|
|
|
|
Enhanced front panel with Russian display and user-programmable pushbuttons
V
|
|
|
|
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
W
|
|
|
|
|
Enhanced front panel with Turkish display
Y
|
|
|
|
|
Enhanced front panel with Turkish display and user-programmable pushbuttons
I
|
|
|
|
|
Enhanced front panel with German display
J
|
|
|
|
|
Enhanced front panel with German display and user-programmable pushbuttons
Summary of Contents for M60 UR Series
Page 10: ...x M60 Motor Protection System GE Multilin TABLE OF CONTENTS ...
Page 128: ...4 30 M60 Motor Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 410: ...5 282 M60 Motor Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 440: ...6 30 M60 Motor Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 452: ...7 12 M60 Motor Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 462: ...9 8 M60 Motor Protection System GE Multilin 9 2 BATTERIES 9 MAINTENANCE 9 ...
Page 474: ...A 12 M60 Motor Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 584: ...B 110 M60 Motor Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 614: ...C 30 M60 Motor Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 630: ...E 10 M60 Motor Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 642: ...F 12 M60 Motor Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 644: ...G 2 M60 Motor Protection System GE Multilin G 1 RADIUS SERVER CONFIGURATION APPENDIX G G ...
Page 652: ...H 8 M60 Motor Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...