GE Multilin
M60 Motor Protection System
6-27
6 ACTUAL VALUES
6.4 RECORDS
6
The starting capacity, starting current, and acceleration time values for the last start are displayed in
ACTUAL VALUES
STA-
TUS
MOTOR
menu. Clearing the motor data (refer to the
Clear records
section in chapter 7) resets these values to their
default.
Figure 6–4: MOTOR LEARNED DATA FUNCTIONALITY
6.4.4 EVENT RECORDS
PATH: ACTUAL VALUES
RECORDS
EVENT RECORDS
EVENT RECORDS
EVENT: XXXX
RESET OP(PUSHBUTTON)
MESSAGE
EVENT: 3
POWER ON
EVENT 3
DATE: 2000/07/14
MESSAGE
EVENT: 2
POWER OFF
EVENT 3
TIME: 14:53:00.03405
MESSAGE
EVENT: 1
EVENTS CLEARED
Date and Time Stamps
Motor running
(status)
Capture starting
thermal capacity
Idle
Capture starting
effective current n
STRT
I > 0 and
I < overload PKP
Capture acceleration
time
Capture thermal
capacity used
Motor stopped
(status)
Capture run time
after start
Store learned acceleration time
Store average run time after start
I
Run
=(I
n-1
Run
,...,I
n-N
Run
)/N
Every 1 minute -
capture load current
Store last acceleration time
Store learned thermal capacity used
Store last thermal capacity used
7
5
6
12
11
10
8
4
2
1
9
3
Store last starting current
Store learned starting current
7
5
6
12
11
10
8
4
2
1
9
3
No
Acceleration time
Successful start
1 minute
Yes
Motor starting
(status)
t
N
n
accel
n
accel
accel
t
t
−
=
,...,
max
I
I
I
N
n
start
n
start
start
−
=
,...,
margin
TCU
Start
TC
,...,
TC
max
TC
×
=
−
N
n
learned
n
learned
learned
avg
N
n
load
n
load
load
t
I
I
I
−
=
,...,
sum
Store average load current every
interval and update display
t
avg
833724A1.CDR
Summary of Contents for M60 UR Series
Page 10: ...x M60 Motor Protection System GE Multilin TABLE OF CONTENTS ...
Page 128: ...4 30 M60 Motor Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 410: ...5 282 M60 Motor Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 440: ...6 30 M60 Motor Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 452: ...7 12 M60 Motor Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 462: ...9 8 M60 Motor Protection System GE Multilin 9 2 BATTERIES 9 MAINTENANCE 9 ...
Page 474: ...A 12 M60 Motor Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 584: ...B 110 M60 Motor Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 614: ...C 30 M60 Motor Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 630: ...E 10 M60 Motor Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Page 642: ...F 12 M60 Motor Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 644: ...G 2 M60 Motor Protection System GE Multilin G 1 RADIUS SERVER CONFIGURATION APPENDIX G G ...
Page 652: ...H 8 M60 Motor Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 662: ...x M60 Motor Protection System GE Multilin INDEX ...