APPX. 4 ALERT LIST
AP-40
Priority: Indication
All indications are in category “B”. The indications are not subject to responsibility transfer and are
not output as ALF sentences.
Note:
Indications also appear in the [Alert] box on the screen and on the [Alert List].
Alert ID
Alert title
Alert Message
ALF
ALR
10001, 1
001
Main Monitor Fan1 Ro-
tation Speed Lowering
There is a problem with No.1 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM1 (Main Monitor). Fan1 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
10001, 2
002
Main Monitor Fan2 Ro-
tation Speed Lowering
There is a problem with No.2 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM1 (Main Monitor). Fan2 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
10001, 3
003
Main Monitor Fan3 Ro-
tation Speed Lowering
There is a problem with No.3 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM1 (Main Monitor). Fan3 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
10001, 4
004
Main Monitor Fan4 Ro-
tation Speed Lowering
There is a problem with No.4 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM1 (Main Monitor). Fan4 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
10001, 5
014
Sub Monitor Fan1 Rota-
tion Speed Lowering
There is a problem with No.1 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM2 (Sub Monitor). Fan1 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
10001, 6
015
Sub Monitor Fan2 Rota-
tion Speed Lowering
There is a problem with No.2 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM2 (Sub Monitor). Fan2 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
10001, 7
016
Sub Monitor Fan3 Rota-
tion Speed Lowering
There is a problem with No.3 Fan of FURUNO Mon-
itor. Please exchange it
Meaning
: For FURUNO monitor: Connected to COM2 (Sub Monitor). Fan3 ro-
tation speed is below threshold.
Remedy
: If the error frequently occurs, contact FURUNO and inform frequency
of occurrence.
Summary of Contents for FAR 3220
Page 201: ...D 1 31 Aug 2022 H MAKI...
Page 202: ...D 2 31 Aug 2022 H MAKI...
Page 203: ...D 3 31 Aug 2022 H MAKI...
Page 204: ...D 4 31 Aug 2022 H MAKI...
Page 205: ...D 5 13 May 2020 H MAKI...
Page 206: ...D 6 13 May 2020 H MAKI...
Page 207: ...D 7 13 May 2020 H MAKI...
Page 208: ...D 8 13 May 2020 H MAKI...
Page 209: ...D 9 31 Aug 2022 H MAKI...
Page 210: ...D 10 31 Aug 2022 H MAKI...
Page 211: ...D 11 13 May 2020 H MAKI...
Page 212: ...D 12 13 May 2020 H MAKI...
Page 213: ...D 13 29 Nov 2017 H MAKI...
Page 214: ...D 14 29 Nov 2017 H MAKI...
Page 215: ...24 Mar 2014 H MAKI D 15...
Page 216: ...24 Mar 2014 H MAKI D 16...
Page 217: ...D 17 8 Jun 2018 H MAKI...
Page 218: ...D 18 8 Jun 2018 H MAKI...
Page 219: ...D 19 8 Jun 2018 H MAKI...
Page 220: ...D 20 11 Jan 2018 H MAKI...
Page 221: ...D 21 11 Jan 2018 H MAKI...
Page 222: ...D 22 11 Jan 2018 H MAKI...
Page 223: ...D 23 11 Jan 2018 H MAKI...
Page 224: ...D 24 11 Jan 2018 H MAKI...
Page 225: ...D 25 11 Jan 2018 H MAKI...
Page 226: ...D 26 14 Jun 2018 H MAKI...
Page 227: ...D 27 14 Jun 2018 H MAKI...
Page 228: ...D 28 14 Jun 2018 H MAKI...
Page 229: ...D 29 28 Feb 2018 H MAKI...
Page 230: ...D 30 8 Jun 2018 H MAKI...
Page 231: ...D 31 13 Jan 2012 Y NISHIYAMA...
Page 232: ...D 32 13 Jan 2012 Y NISHIYAMA...
Page 233: ...D 33 13 Jan 2012 Y NISHIYAMA...
Page 234: ...D 34 13 Jan 2012 Y NISHIYAMA...
Page 235: ...D 35 6 Feb 2020 H MAKI...
Page 236: ...D 36 25 Mar 2021 H MAKI...