BX924 S3
Upgrade and Maintenance Manual
51
Basic hardware procedures
Ê
Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 59
.
Ê
Open the server blade as described in section
"Opening the server blade"
on page 60
.
Ê
Press the Indicate CSS button (1) to highlight defective components.
Component LEDs
I
LEDs C to G are visible from the frontside. All other LEDs are only visible
if the server blade cover has been removed. In order to access memory
LEDs (B), the air cowls need to be removed (see section
"Handling of
memory air cowls" on page 178
).
Indicator Status
Description
A
Mezzanine
card 1
off
Mezzanine card 1 operational
orange on
Mezzanine card 1 failure
B
Memory
off
memory module operational
orange on
memory module failure
C
Fabric 3/4
off
Fabric 3/4 no link
green
flashing
Fabric 3/4 link active
green on
Fabric 3/4 link established
D
Fabric 2
off
Fabric 2 no link
green
flashing
Fabric 2 link active
green on
Fabric 2 link established
E
Fabric 1
off
Fabric 1 no link
green
flashing
Fabric 1 link active
green on
Fabric 1 link established
F
CSS
off
System is ok
yellow
flashing
CSS error detected
yellow on
Prefailure event detected
Summary of Contents for PRIMERGY BX924 S3
Page 6: ...Upgrade and Maintenance Manual BX924 S3 ...
Page 16: ...16 Upgrade and Maintenance Manual BX924 S3 ...
Page 20: ...20 Upgrade and Maintenance Manual BX924 S3 Introduction ...
Page 42: ...42 Upgrade and Maintenance Manual BX924 S3 Important information ...
Page 68: ...68 Upgrade and Maintenance Manual BX924 S3 Basic hardware procedures ...
Page 104: ...104 Upgrade and Maintenance Manual BX924 S3 Basic software procedures ...
Page 180: ...180 Upgrade and Maintenance Manual BX924 S3 Main memory ...
Page 232: ...232 Upgrade and Maintenance Manual BX924 S3 Processors ...
Page 278: ...278 Upgrade and Maintenance Manual BX924 S3 System board components ...