
208
Upgrade and Maintenance Manual
BX924
S3
Processors
Ê
Shut down the server blade as described in section
"Shutting down the
server blade" on page 54
.
Ê
Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 59
.
Ê
Open the server blade as described in section
"Opening the server blade"
on page 60
.
Ê
If necessary, remove the memory as described in section
"Removing a
memory module" on page 173
.
Ê
Remove the desired processor heat sink as described in section
"Removing
processor heat sinks" on page 227
.
9.4.3
Upgrading or replacing a processor
9.4.3.1
Removing the processor
Figure 78: Opening socket release lever 1
Summary of Contents for PRIMERGY BX924 S3
Page 6: ...Upgrade and Maintenance Manual BX924 S3 ...
Page 16: ...16 Upgrade and Maintenance Manual BX924 S3 ...
Page 20: ...20 Upgrade and Maintenance Manual BX924 S3 Introduction ...
Page 42: ...42 Upgrade and Maintenance Manual BX924 S3 Important information ...
Page 68: ...68 Upgrade and Maintenance Manual BX924 S3 Basic hardware procedures ...
Page 104: ...104 Upgrade and Maintenance Manual BX924 S3 Basic software procedures ...
Page 180: ...180 Upgrade and Maintenance Manual BX924 S3 Main memory ...
Page 232: ...232 Upgrade and Maintenance Manual BX924 S3 Processors ...
Page 278: ...278 Upgrade and Maintenance Manual BX924 S3 System board components ...