228
Upgrade and Maintenance Manual
BX924
S3
Processors
9.5.5
Removing the "dummy heat sink" of CPU 2
I
In case that no CPU 2 is installed, a "dummy heat sink" will be installed
for cooling reasons.
Figure 97: Removing the "dummy heat sink" of CPU 2
Ê
Loosen the four captive screws (combihexagon) of the "dummy heat sink" in
the following pattern: (4)->(3)->(2)->(1) (see figure).
Ê
Lift the "dummy heat sink" out of the chassis.
V
CAUTION!
Pay special attention not to damage any system board components
surrounding the processor socket.