BX924 S3
Upgrade and Maintenance Manual
109
Solid state drives
6.3.4
Installing SSD 0
Ê
Remove the mezzanine carrier as described in section
"Removing
mezzanine cards" on page 148
.
Ê
Choose the desired mounting frame (PCH or SAS) for SSD 0.
Figure 17: Securing the drive
Ê
Shift the drive into the connector on the mounting frame (1).
Ê
Secure the drive with 4 screws (see arrows). Torque: 0.6 Nm (not applicable
for the Japanese market)