![background image](http://html.mh-extra.com/html/fujitsu/primergy-bx924-s3/primergy-bx924-s3_upgrade-and-maintenance-manual_121030057.webp)
BX924 S3
Upgrade and Maintenance Manual
57
Basic hardware procedures
4.4.2
Replacing steps
Ê
Open both server blades, see section
"Opening the server blade" on
page 60
.
Ê
Remove the heat sinks from and the processors from the defective server
blade and install it into the new server blade, see section
"Handling
processor heat sinks" on page 218
and install it into the new server blade,
see section
"Upgrading or replacing processors" on page 207
.
Ê
Remove the mezzanine card carrier with the installed mezzanine card(s)
from the defective server blade, see section
"Replacing mezzanine cards"
on page 152
.
Ê
Remove the memory modules from the defective server blade and install it
into the new server blade, see section
"Replacing memory modules" on
page 175
.
Ê
If an UFM is installed, remove it from the defective server blade and install it
into the new server blade, see section
"USB Flash Module (UFM)" on
page 239
.
Ê
If an TPM is installed, remove it from the defective server blade and install it
into the new server blade, see section
"Trusted Platform Module (TPM)" on
page 251
.
Ê
If an SCU key is installed, remove it from the defective server blade and
install it into the new server blade, see section
"Onboard Controller SAS
Upgrade ROM (SCU key)" on page 266
.
Ê
Install the mezzanine card carrier into the new server blade, see section
"Replacing mezzanine cards" on page 152
.
Ê
Use the cover from the defective server blade and close the server blade,
see section
"Closing the server blade" on page 61
.
Use the cover from the defective server blade because the COA label is
stuck there.
I
It is necessary to complete ID card with the model name and the serial
number. Please use the new label.
Summary of Contents for PRIMERGY BX924 S3
Page 6: ...Upgrade and Maintenance Manual BX924 S3 ...
Page 16: ...16 Upgrade and Maintenance Manual BX924 S3 ...
Page 20: ...20 Upgrade and Maintenance Manual BX924 S3 Introduction ...
Page 42: ...42 Upgrade and Maintenance Manual BX924 S3 Important information ...
Page 68: ...68 Upgrade and Maintenance Manual BX924 S3 Basic hardware procedures ...
Page 104: ...104 Upgrade and Maintenance Manual BX924 S3 Basic software procedures ...
Page 180: ...180 Upgrade and Maintenance Manual BX924 S3 Main memory ...
Page 232: ...232 Upgrade and Maintenance Manual BX924 S3 Processors ...
Page 278: ...278 Upgrade and Maintenance Manual BX924 S3 System board components ...