BX924 S3
Upgrade and Maintenance Manual
117
Solid state drives
Ê
Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 59
.
Ê
Open the server blade as described in section
"Opening the server blade"
on page 60
.
6.4.3
Removing SSD 0
Ê
Remove the mezzanine carrier as described in section
"Removing
mezzanine cards" on page 148
Figure 25: Removing SSD 0 from the mounting platform
Ê
Loosen the knurled screw of the mounting kit (1).
Ê
Unplug the mounting kit from the connector by lifting it off from the mounting
platform (2).
Ê
Slide the mounting kit out of the cut-out (3) of the mounting platform.