219
27. Connecting to Routers
The switcher can also connect to a router other than FOR-A MFR series routers.
The router control is based on the HARRIS Pass-Through protocol.
To connect a router other than an MFR series router, two RS-422 interfaces, one for
controlling the router and the other for receiving TSL protocol, are required.
27-1. Assigning a Router Channel to an RS-422 port
(1) Display the [SETUP - SYSTEM - RS-422] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>
RS-422
>TIME >INIT >REBOOT
(2) Turn F1 to select a port for connecting a router.
(3) Select ROUTER under
FUNC
.
(4) Set
BAUD
(baudrate) to 57600 and
PARITY
to NONE. (These settings may vary depeding
on routers. Refer to your router's User Manual.)
SYSTEM :SELECT :FUNC :BAUD :PARITY : 1/1
RS-422 : =
PORT1
:=
ROUTER
: =57600: =NONE :
(5) Reboot the switcher after settings are complete. (See section 23-1. "Rebooting System.")
27-2. Router Control
The router can be controlled in the same way as described for MFR series routers. See section
26-2. "Router Control."
27-3. Linking Titles and Tallies in the System via TSL Protocol
HVS-390HS
Router
RS-422
RS-422
2
Multiviewer
(UMD)
RS-422
3
RS-422
TSLRx
(Receive)
TSL
(Send)
RS-422
4
RS-422
1
RS-422
Router control
Video titles
Video titles
& Tallies