![FOR-A HVS-390HS Operation Manual Download Page 225](http://html1.mh-extra.com/html/for-a/hvs-390hs/hvs-390hs_operation-manual_2316756225.webp)
225
30. AUX Bus Control Units
30-1. HVS-AUX8/16/32
HVS-AUX8/16/32 units allow you to remotely change an AUX bus signal. An AUX unit can
control a single AUX output. HVS-AUX8 units can select up to 8 signals (14 if using SHIFT).
HVS-AUX16/32 units can select combined signals (PGM, PREV, and CLEAN) as well as input
signals. Up to 5 AUX units can be connected to the switcher.
30-1-1. Connecting AUX Units
AUX units are connected to the switcher through a specialized
ARCNET
network.
Connect AUX units to the switcher in a cascade as shown below and terminate both ends of
the network chain with 75-ohm terminators.
ARCNET ID Numbers
Arncet ID numbers from
1 to 255
are used to uniquely identify a network terminal.
The Arcnet ID number for
HVS-390HS
is set to
250
as factory default.
Note: Do
not
duplicate an Arcnet ID number.
See the "HVS-AUX8/16/32 Operation Manual" for more details.
Use an Arcnet Hub (up to 2 units) if the total cable
length
exceeds
100
m.
To Change the Switcher ARCNET ID Number
The Arcnet ID number for
HVS-390HS
is set to
250
and an OU is set to
1
as factory default
and does not normally need to be changed. Change the ID number in the [SETUP - SYSTEM
- ARCNET] menu only when necessary.
SYSTEM : OU ID :OU NO :CTRL MU : : 1/2
ARCNET : = 1 :=OU1 : =250 : :
SYSTEM : MU ID : : 2/2
ARCNET : = 250 : :
To apply the change, turn the switcher power Off, then On.
75
Ω
terminator
Arcnet cable: 75
Ω
BNC (5C2V equivalent or higher)
Total cable length: Less than 100 m
HVS-AUX8
(for AUX1)
HVS-AUX8
(for AUX2)
HVS-AUX16
(for AUX3)
HVS-AUX16
(for AUX4)
1 m or more
for each
ID
240
ID
241
ID
242
ID
243
HVS-390HS rear panel
HVS-392OU/ROU/WOU rear panel
Arcnet ID
1
EDITOR
OPTION SLOT
AC100-240V 50/60Hz IN
2
RS-422
AUX
HDMI
GPI IN
SDI OUTPUT
1
2
A
B
1
2
1
2
3
4
5
6
7
8
SDI INPUT
9
10
11
12
13
14
16
15
GPI/TALLY OUT
OPTION SLOT
C
D
1
AC100-240V 50/60Hz IN
RATING LABEL
TO OU
GENLOCK
REF IN
REF OUT
LAN
1
2
3
4
5
6
3
4
5
6
CONTROL
TO MU
(SERVICE)
GPI /TALLY OUT
RATING LABEL
OFF
ON
POWER
POWER 2
POWER 1
AC100-240V 50/6 0Hz IN
Arcnet ID