244
34-2. Upgrading HVS-390HS
(1) Insert the USB flash memory that contains the upgrade data into the USB port.
(2) Press MENU in the CONTROL block, then press FILE to open the FILE top menu.
(3) Turn F1 to select UPDATE, and then press F1 or the page down button to open the [FILE -
UPDATE] menu.
FILE :>LOAD >SAVE >
UPDATE
TOP :
FILE : EXT : LOAD : <DIR> 1/1
UPDATE : =
MCB
: : XXXXXXXX 101MB
(3) Turn F1 to select MCB to the
EXT
(File Extension) item.
(4) Turn F3 to select an MCB file.
(5) Press F3 to start upgrading.
IMPORTANT
DO NOT turn the power of your units OFF or try to remove the USB flash memory from
the port until the file downloads are complete!
(6) In the [FILE-UPDATE] menu screen the pop-up status window appears showing the file
transfer progress.
(7) The lamp buttons on the panel will go dark after 30 seconds. (The data starts writing to the
switcher flash ROM.)
(8) After about 1 minute, panel indications will return to normal. (Download / ROM write
complete.)
(9) When the HVS-390HS is automatically restarted, the upgrade is successfully complete.
IMPORTANT
Proceed to upgrade your switcher system with other upgrade files in the same manner
as that of the above HVS-390HS upgrade. To complete upgrade procedures,
however, restart the switcher system manually.
Installation times are:
Approximately 4 minutes for MCB, MDB, MDH and MFB files respectively
Approximately 10 seconds for OCD, OFB, OUF and RUB files respectively
34-3. Loading Setting Data
All previously set switcher menu settings can be reset by loading the "DATA.ALL" file from the
USB Disk.
(1) Insert the USB flash memory device with saved data into the USB port.
(2) Press FILE to display the top page of the FILE menu.
(3)Turn F1 to select LOAD, then press F1 or the page down button to display the [FILE - LOAD]
menu.
(4) Turn F1 to select ALL to the
EXT
(File Extension) item.
(5) Turn F3 to select data. (The file name of the data must be "DATA.ALL", if it is not renamed.)
(6) Press F3 (or F2) to start loading the file.
(7) The data transfer will take approx. 30 minutes to complete.
(8) After loading the data, reboot the switcher.