160
17-3. Sequence Memory Operation Examples
17-3-1. Setting Overwrite Protection on Sequence Memory 2
(1) Press SEQUENCE to display the [SEQUENCE MEMORY] menu.
(2) Press 2 to select "Sequence Memory 2." The button light turns on and the [SEQUENCE
RECALL] menu appears.
(3) Press the page down button to go to PAGE 2 of the menu.
(4) Press F1 to change
OVER WR
(overwrite) to DISBL (disable)
to set "Sequence Memory
2" to be protected from data change.
SEQUENCE:OVER WR:DELETE : : 2/2
RECALL : =
DISBL
: >OFF : :
17-3-2. Deleting "Sequence Memory 2"
(1) Press SEQUENCE to display the [SEQUENCE MEMORY] menu.
(2) Press 2 to select "Sequence Memory 2." The button light turns on and the [SEQUENCE
RECALL] menu appears.
(3) Press the page down button to go to PAGE 2 of the menu.
(4) Press F2 to set
DELETE
to ON and press F2. The data in "Sequence Memory 2" is
cleared.
SEQUENCE:OVER WR:DELETE : : 2/2
RECALL : =ENABL: >
ON
: :
17-4. Backing up Sequence Data
The following procedure shows how to save the sequence data to USB memory stick.
(1) Insert a USB flash memory into the USB port.
(2) Press MENU in the CONTROL block, then press FILE to open the [FILE] top menu.
(3) Turn F1 to select SAVE, and then press F1 or the page down button to open the [FILE -
SAVE] menu.
(4) Turn F1 to select ALL (or SEQ) to the
EXT
(File Extension) item.
(5) Turn F3 to select data (or "SEQDAT02.seq" for example). Press F3 to save the data to USB
memory.
FILE : EXT : CTRL : DATA.ALL : 1/1
SAVE : =
ALL
: =SAVE : : 101MB
(6) When the data is sent to the flash memory, the message "SAVE?" will appear. Press F3
again to store the data to the flash memory. A "beep" sound will be heard when the data is
saved.