![FOR-A HVS-390HS Operation Manual Download Page 229](http://html1.mh-extra.com/html/for-a/hvs-390hs/hvs-390hs_operation-manual_2316756229.webp)
229
30-2-3. Assigning the SHIFT or TAKE Function
HVS-AUX16A/16B/32A units can use additonal 16/32 buttons by using the SHIFT function. In
addition, HVS-AUX16A/16B/32A/64A units can use the TAKE (confirmation) function.
Note that the SHIFT and TAKE functions cannot be used simultanelusly. The TAKE function
is always enabled by setting TAKE to ON in the menu regardless of SHIFT state.
Using the SHIFT function
(1) Open [SETUP - EXT I/F - AUX UNIT] menu PAGE 2.
(2) Select
TGL
(Toggle) or
NOR
(Normal) under
SHIFT
.
(3) Set
TAKE
to
OFF
.
AUX UNIT: BRIGHTNESS : SHIFT : TAKE : 2/5
SELECT : H=8 L=1 : =
TGL
: =
OFF
:
With these settings, HVS-AUX16A/16B/32A units can use additonal 16/32 buttons using
the SHIFT/TAKE button. Refer to the table in the next page for details on how to use this
button.
Parameter
Default
Setting
Description
SHIFT OFF
OFF
Additional buttons cannot be used.
TGL
Pressing the SHIFT/TAKE button enables SHIFT and
pressing the button again disables SHIFT.
NOR
SHIFT is enabled while the SHIFT/TAKE button is
pressed.
Using the TAKE (Confirmation) Function
(1) Open [SETUP - EXT I/F - AUX UNIT] menu PAGE 2.
(2) Set TAKE to ON.
Parameter
Default
Setting
Description
TAKE OFF
OFF
An action is immediately executed (by pressing the
action button) without pressing TAKE.
ON
An action is executed by pressing TAKE after pressing
the action button.
Press TAKE within 5 seconds after pressing an action
button. Otherwise, the operation will be canceled.
30-2-4. Adjusting Light Levels for AUX Unit Buttons
Light levels for AUX unit buttons can be adjusted in [SETUP - EXT I/F - AUX UNIT] menu
PAGE 2 as shown below.
AUX UNIT: BRIGHTNESS : SHIFT : TAKE : 2/5
SELECT : H=
8
L=
1
: =OFF : =OFF :
Parameter
Default
Setting
Description
BRIGHTNESS
H
8
5 - 8
Adjusts the normal lighting level.
L
1
0 - 4
Adjusts the dim lighting level.