![FOR-A HVS-390HS Operation Manual Download Page 240](http://html1.mh-extra.com/html/for-a/hvs-390hs/hvs-390hs_operation-manual_2316756240.webp)
240
33. Status Information
The STATUS menu indicates the current status of the cooling fan, power and genlock and the
versions of hardware and software.
33-1. Checking Alarm Status
(1) Open the [SETUP - STATUS] menu. Turn F1 to select ALARM, then press F1 or the page
down button to display the submenu.
SETUP :>
ALARM
>VERSION >OPTION
STATUS :
(2) The STATUS submenus display the current status of the cooling fan, power and genlock as
shown below.
STATUS :FAN1:NOR 2:NOR : 1/3
MU ALARM: PS1:NOR 2:NOR :
STATUS : GENLOCK:External Lock : 2/3
MU ALARM:MEM CARD:Installed :
STATUS : PS1:NOR 2:NOR : 3/3
OU ALARM: :
Item
Display
Description
FAN1
FAN2
NOR
Indicates that FAN works properly.
ERR
Indicates that FAN has failed. Power off the switcher and
consult your FOR-A reseller.
PS1
PS2
NOR
Indicates that POWER works properly.
ERR
Indicates that POWER has failed. Power off the switcher
and consult your FOR-A reseller.
GENLOCK
External
Lock
Indicates that a valid reference signal is present and video
signals are properly locked to the reference signal.
Internal
Lock
Indicates that the internal reference is being used.
In such case, a reference signal is not present, its level is too
low. Or a reference signal with a different format from the
switcher is present.
MEM CARD
Installed
Indicates that the standard still/clip memory card is properly
installed and the memory can be used.
Not
installed
Indicates an error in the still/clip memory card. It is not
properly installed or the card may be broken.