184
21-6-2. AUX and Optional Outputs
Ancillary data for AUX outputs are set on PAGE 2 of the [SETUP - OUTPUT - ANCI] menu.
Choose an output for setting under
SELECT
. Then select ON (pass) or OFF (blank).
OUTPUT :SELECT :ENABLE : : 2/2
ANCI THR: =AUX1 : =
ON
: :
21-7. Setting Date and Time
(1) Press MENU in the CONTROL block, then press SETUP to display the SETUP top menu.
Turn F1 to select SYSTEM, then press F1 or the page down button to open the [SETUP -
SYSTEM] menu.
(2) Turn F1 to select TIME, then press F1 or the page down button to open the [SETUP -
SYSTEM - TIME] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>RS-422 >
TIME
>INIT >REBOOT
(3) If you need to change the date, turn F1 to select Month, Day or Year, then turn F1 to change
the setting.
(4) If you need to change the time, turn F3 to select Hour, Minute or Second, then turn F3 to
change the setting.
SYSTEM : DATE(mm/dd/yy):TIME[10:20:10] : 1/1
TIME : =Jul/14/10 : =10:20:20 :
NOTE
The date and time are used for the multiviewer clock and recording data backup time.
Note that if the switcher is turned OFF within 100 hours (or less if it is not fully
charged), date and time data will be cleared. In such case, reset the date and time.
21-7-1. Setting Time Using SNTP (Time) Server
The switcher time can be synchronized to a time (SNTP) server using the Simple Network
Time Protocol (SNTP).
To synchronize the time to a SNTP server time, enter the IP address of your SNTP server, set
the time zone, then update the time manually. After time settings are completed, it is
recommended to turn on automatic updates (at start-up and/or fixed time).
The SNTP server time may not be correct due to the network delay or other reasons.To
improve the time precision, locate a SNTP server in your local network zone.
Setting the IP address of SNTP Server
(1) Open [SETUP - SYSTEM - TIME] menu PAGE 3.
(2) Press F1 to highlight the first octet (192 in the menu example above) of the IP address.
SYSTEM :SNTP SERVER IP ADDRESS :UPDATE : 3/4
TIME : =
192
.168.000.011 : >EXEC :
(3) Turn F1 to change the value and press F1.
(4) Repeat Steps (2) and (3) to set the server IP address.