145
16-5. Setting the User Default Menu when Storing an Event
The [EVENT STORE] menu appears as shown below in the factory default setting when storing
events.
EVENT :SELECT : XPT : DATA : RATE : 1/3
STORE : =ALL : =ON : =ON : =OFF :P.00
EVENT :AUX SEL:AUX RCL:KEY ASG:SEQ RCL: 2/3
STORE : =ALL : =OFF : =OFF : =OFF :P.00
EVENT :CG WIPE:OVER WR:DELETE : : 3/3
RECALL : =OFF : =DISBL: >OFF : :P.01
Changing the default setting of the [EVENT STORE] menu is possible. To do this, proceed as
follows.
(1) Press EVENT in the MEMORY block. The [EVENT MEMORY] menu is displayed.
(2) Change the following menu items to the desired settings, which become the default settings
in the [EVENT MEMORY] menu. (Only highlighted items are changeable.)
EVENT : PAGE :DIRECT :PAGECLR: RATE : 1/3
MEMORY : =0 : =OFF : =OFF : =
OFF
: L=0
EVENT :AUX BUS:KEY ASG:SEQ RCL:M/E BUS: 2/3
MEMORY : =
OFF
: =
OFF
: =
OFF
: =ALL : L=0
EVENT :CG WIPE: : 3/3
MEMORY : =
OFF
: : L=0
16-6. Loading an Event at Start-up
The settings made for the background and key buses on the control panel are cleared when
powering off the switcher. You can, however, recall the desired panel setup whenever the
switcher starts by setting in the [SETUP - SYSTEM - INIT] menu as shown in the procedure
below.
(1) Press MENU in the CONTROL block.
(2) Press SETUP to display the SETUP menu top page.
(3) Turn F1 to select SYSTEM and then press F1.
SETUP :>
SYSTEM
>INPUT >OUTPUT >PANEL
MENU :>GPI/TLY >FUNCTION>EXT I/F >STATUS
(4) The [SETUP - SYSTEM] menu as shown below appears. Turn F1 to select INIT and then
press F1 to display the [SETUP - SYSTEM - INIT] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>RS-422 >TIME >
INIT
>REBOOT
SYSTEM : INIT : LOAD : : 1/1
INIT : >CURRENT : =
LAST
: :