The Panda Generator
22.3.11
Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 4: The Panda Generator Page 37
Heat exchanger
Separates the raw water system from the
freshwater system.
Fig. 4.3.1-4: Heat exchanger
Ventilation valve
A siphon must be installed if the generator
sinks below the water line because of the
rocking of the boat, even if it is only for a
short period of time. A hosepipe on the
generator casing has been produced for
this. Both connecting pieces are bridged
by a formed piece of hose.
Fig. 4.3-5: Connection ventilation valve
Cooling water injector nozzle
The injection point for the marine genera-
tor water-cooled exhaust system is situa-
ted at the exhaust connection pieces The
exhaust connections must be regularly
checked for signs of corrosion.
Fig. 4.3-6: Cooling water injector nozzle